SVMS Steam
Quality
Clean/Pure Steam Condenser (Sanitary cooler) & Components
Where
steam is in direct contact with items which, in turn, may
be in direct contact with patients, any contaminants present
in the steam supply may be introduced into bodily cavities.
For this test, a sample of condensed steam is collected
with depyrogenated equipment into a sterile pyrongen-free
container. The sample is then analysed by a laboratory to
determine the level of chemical impurities and bacterial
endotoxins.
The 316 stainless steel clean steam condenser is very efficient
and compact. The condensate sample is collected cleanly
due to the design shape of the condenser outlet. The condenser,
pitot tube, isolating valve and steam supply tubing may
be depyrogenated in a suitably validated Dry Heat sterilizer/Oven
at 180 degrees centigrade for 3 hours prior to use.
•
Superheat
• Dryness
value
• Non-Condensable
Gases
• Back to SVMS
Steam Quality Test Kits